Partial Interval Recording in ABA: Scoring and Examples

Partial Interval Recording in ABA: Scoring and Examples

Partial interval recording (PIR) in ABA is a data collection method that divides an observation into short intervals of the same length. It scores an interval if the target behavior happens at any point during it. One instance is enough for a yes, and results are shown as the percent of intervals scored yes.

This article will help you set up PIR, score it and read the results for your ABA practice.

Key takeaways

  • One instance scores the interval: Partial interval recording marks an interval as yes if the behavior happens even briefly, so it shows whether a behavior occurred without counting how often.
  • Best for behaviors to reduce: The method suits brief, fast behaviors with no clear start or end, such as calling out, when the goal is to reduce them.
  • It overestimates behavior: One short episode scores the whole interval, so partial interval data run higher than a stopwatch would show.
  • More time for your graphs: If you'd like someone else to handle billing while you focus on behavior data, look at what Alpaca Health offers.

What is partial interval recording?

Partial interval recording is a discontinuous measurement method. These methods record a sample of the behavior and miss some of what happens. With PIR, an observer watches each interval and scores it if the target behavior occurs at any time within it. The interval gets one mark no matter how many times the behavior happens or how long it lasts.

The Behavior Analyst Certification Board (BACB) lists discontinuous measurement as task A.2 in the RBT Test Content Outline. PIR is one of three interval methods there. Whole interval recording gives a yes only when the behavior fills the entire interval. Momentary time sampling (MTS) scores only what is happening as the interval ends.

PIR is also the most common of these methods for problem behavior in published research (LeBlanc and colleagues, 2020).

Let Alpaca Health draft your session notes.

Alpaca Health's HIPAA-compliant platform includes AI session notes and data collection, so your team spends less time on paperwork.

See it in action →
A behavior analyst and child doing an activity

When to use partial interval recording in ABA

PIR works best for brief behaviors that are hard to count and for goals that aim to reduce a behavior.

  • Brief, fast behavior with no clear start or end: Calling out and hitting can happen in quick bursts that are hard to count one by one, and PIR only asks whether the behavior happened in each interval.
  • Behavior to reduce: Fiske and Delmolino (2012) say PIR fits behavior-reduction goals but is very strict. Since PIR runs high, a behavior has to nearly stop before the data show a large drop.
  • Behavior that must stop completely: When any occurrence matters, such as eye gouging or other severe self-injury, PIR shows which intervals still had the behavior. Fiske and Delmolino add that among the interval methods, only PIR captures a goal of zero accurately.
  • Changes in how often a brief behavior happens: Simulation research by Rapp and colleagues (2008) found that of the interval methods they tested, only PIR with 10-second intervals reliably caught most changes in brief, countable behaviors.

If you can count or time each instance, continuous measurement is the better choice. When a behavior lasts a while or needs to increase, duration recording or MTS fits better.

How to set up partial interval recording

Setting up PIR takes four steps, starting with a clear definition and ending with a ready data sheet and timer.

Define what counts as an occurrence

An operational definition states exactly what the behavior looks like. Any observer using it would score the same interval the same way. For humming, a definition might be "any closed-mouth vocal sound lasting at least 1 second that isn't speech." Clear examples and non-examples keep a cough or a sigh from being scored.

Choose the interval length

The interval length works best when it's short, since longer intervals make PIR run higher. Ten-second intervals are the most common choice in research, but even they usually run high. In a simulation by Wirth and colleagues (2014), error was smallest when the interval was no longer than a typical episode. With very brief behaviors, an interval that short is hard to score. Choose the shortest one your RBT can score reliably, and expect the percent to run high.

Keep the same interval length across sessions, because a switch from 10 to 15 seconds changes the percent even when the behavior stays the same.

Set the observation period

The observation period is the total time PIR runs, such as a 5-minute table-work block or a 30-minute play session. Picking a time when the behavior usually happens gives the most useful data. In Wirth and colleagues' simulation, a longer observation made PIR data steadier but didn't make the overestimate any smaller. Keep the observation the same length across sessions, so a short session's bigger swings don't look like a change in behavior.

Prepare the data sheet and timer

The data sheet lists each interval in order, with space to mark a yes or a no. The top holds session details and the definition. The bottom has room for the total and the percent of intervals. A vibrating timer or a data collection app that signals each new interval keeps the observer on track without looking at a clock.

How to score partial interval data

Score PIR data with the same four rules each time, so the data stay consistent across sessions and observers.

  • Mark the interval once at the first occurrence: As soon as the behavior happens, the interval gets a yes, and the observer can stop watching for that behavior until the next interval starts.
  • Score a behavior that carries over in both intervals: If an episode starts near the end of one interval and continues into the next, both intervals get a yes.
  • Mark empty intervals when they end: An interval gets a no only after it finishes with no occurrence, since the behavior could still happen in the last second.
  • Turn the total into a percent of intervals: Divide the number of yes intervals by the total number of intervals and multiply by 100.

Following these rules lets you check PIR data through interobserver agreement (IOA). In an IOA check, a second observer scores the same session, and you compare the two records.

Partial interval recording example

In this example, an RBT tracks one learner's humming with PIR during a 5-minute table-work block. Humming is usually a harmless stim that BCBAs leave alone. The team targets it here only because it consistently keeps the learner from doing table work. The RBT uses 10-second intervals, which gives 30 intervals in total.

During the block, the learner hums 8 times. Each hum lasts 2 to 4 seconds, and two of them start near the end of one interval and carry into the next. Under the carry-over rule, those two hums each score two intervals. The other six score one interval each, so humming shows up in intervals 1, 2, 3, 5, 8, 12, 13, 17, 21 and 27. That's 10 of the 30 intervals, or 33% of intervals.

A second observer records the same block with a counter and a stopwatch. The table below compares the four ways of measuring the same humming.

MeasureResult
Count8 episodes
Timed total26 seconds, or about 9% of the block
PIR with 10-second intervals10 of 30 intervals, or 33%
PIR with 30-second intervals8 of 10 intervals, or 80%

The learner hums for about 9% of the block, but 10-second PIR shows 33% of intervals. If you read only the 10-second PIR graph, you might think humming takes up a third of table work. When the same block is rescored with 30-second intervals, the result jumps to 80%. The behavior doesn't change at all, which shows how much interval length drives the percent.

Cut admin time in your ABA practice.

Alpaca Health handles credentialing, authorizations, claims, and payroll for BCBAs who own an ABA practice. You keep full clinical control.

See how it works →
A person reviewing notes on a phone

Why does partial interval recording overestimate behavior?

Partial interval recording overestimates the share of time a behavior takes up, because a single brief occurrence counts the whole interval as a yes. A 2-second hum in a 10-second interval looks the same on the data sheet as 10 seconds of humming.

Episodes that cross an interval boundary also score twice. With longer intervals, each brief episode marks even more time as a yes.

In 1975, Powell and colleagues tracked one secretary's time in her seat. In that study, PIR consistently ran higher than the continuous record. The authors found that the size of the error depends on how long each response lasts on average. They also found that the error won't stay the same across conditions, such as baseline and treatment.

PIR can also underestimate how often a behavior happens when it occurs many times in one interval. Five hums in the same 10 seconds still count as one yes, so high-rate behavior can look lower than a count would show.

How does partial interval data affect treatment decisions?

Partial interval data affects treatment decisions because the overestimate can hide real progress or suggest progress that isn't there. Even so, Meany-Daboul and colleagues (2007) found that conclusions from 10-second PIR mostly matched those from frequency or duration data. In their study, nine BCBAs judged the same treatment data graphed three ways. Against the duration data, 6 of 27 conclusions were incorrect with PIR and 3 of 27 with MTS.

Count or time the behavior for a few sessions before you change a learner's behavior intervention plan because of a PIR graph. Then check whether those data show the same change.

Decreases that may not show

A behavior can drop without the PIR percent moving much. If a learner goes from six hums per interval to one, each interval still gets a single yes, and the graph looks flat. The same happens when episodes get shorter but still occur in each interval.

Harrop and Daniels (1986) found in a computer simulation that PIR tended to understate how much a high-rate behavior changed. Rapp and colleagues' 2008 simulation found that 10-second PIR caught only about half of the changes in behaviors that last a while. If a PIR graph stays flat after treatment starts, Fiske and Delmolino suggest watching the data longer. If the change is still too small for PIR to show, they suggest changing the treatment so the behavior drops further.

Changes that may not be real

PIR can also show a change that didn't happen, which is called a false positive. In Rapp and colleagues' 2008 simulation, 10-second PIR gave a fairly high rate of false positives for behaviors that last a while. With real behavior, Schmidt and colleagues (2013) found few false positives for those behaviors. They found an unexpectedly high rate for brief, countable ones. Since the two studies disagree, treat a sudden change on a PIR graph with caution for either kind of behavior.

Fiske and Delmolino describe long, rare tantrums that turn into short, frequent ones with the same total time. PIR can show that as a rise in tantrums. A change in interval length between phases can create the same kind of false shift.

Common partial interval recording mistakes to avoid

Common PIR mistakes come from using it for the wrong behavior or trusting its numbers too much.

Using it for behaviors to increase

Using PIR for behaviors you want to increase makes progress look bigger than it is. A learner who plays with peers for a few seconds per interval would score high, even with very little play.

Fiske and Delmolino give the example of a child on task for 3 seconds per 10-second interval. Over a 5-minute block, that's 90 of 300 seconds, or 30%, but PIR scores all 30 intervals, or 100%. Duration recording or MTS often fits these goals better. Whole interval recording also works if you want a strict measure.

Using it when duration data is needed

Using PIR when you need to know how long a behavior lasts gives a number that overstates the time. Gardenier and colleagues (2004) studied stereotypy in young children with autism. They found that 10-second PIR grossly overestimated how much of the time it took up. MTS made much smaller errors in both directions. Duration recording measures the time directly, and MTS gives a closer estimate than PIR.

Looking only at the end of each interval

Looking only at the end of each interval turns PIR into MTS and misses occurrences earlier in the interval. PIR depends on observers watching each interval until the behavior happens or the interval ends. Practicing this during behavior skills training helps new RBTs build the habit. If an RBT can't keep watching while teaching, ask another staff member to take the data or plan MTS from the start.

Trusting high IOA scores

High IOA scores on PIR data can hide accuracy problems, since two observers can agree and still both overestimate. With high-rate behavior, nearly every interval gets a yes, so agreement looks high by default. Rapp and colleagues (2011) rescored sessions that had 89% agreement or less on continuous duration data. With 10-second PIR, the agreement scores were consistently higher.

For a stricter check with low-rate behavior, use scored-interval IOA, which ignores the intervals neither observer scored. With high-rate behavior, use unscored-interval IOA, which ignores the intervals both observers scored.

How Alpaca Health helps you track behavior reduction in your ABA practice

Alpaca Health helps you track behavior reduction with one HIPAA-compliant platform for behavior data and progress tracking. The same platform handles scheduling and billing. Clinical decisions stay with you, including whether a PIR graph should change a learner's treatment plan.

Alpaca Health's billing team verifies benefits and gets authorizations. It also submits each insurance claim and works any denied claim through appeals. AI session notes cut down the note writing your RBTs do at the end of a session. Payment to your practice is guaranteed every two weeks, and a delayed or denied claim doesn't hold it up.

If billing and authorizations take time away from your behavior data, book a demo.

See what your ABA practice could look like on Alpaca Health.

A demo walks you through AI session notes, billing, credentialing, and payroll on Alpaca Health.

Book a demo →
Two people shaking hands

Frequently asked questions about partial interval recording

What does partial interval recording measure?

Partial interval recording measures the percent of intervals in which a behavior occurred at least once. It doesn't measure exact frequency or duration. LeBlanc and colleagues (2016) describe it as an estimate of both. You can check how close the estimate runs by counting or timing the same behavior with continuous measurement now and then.

How is partial interval recording different from frequency recording?

PIR scores whether a behavior happened in each interval, while frequency recording counts each instance. Five hums in one interval count as one yes with PIR and five with a count. Frequency data collection works better when each instance is easy to see and count.

Can you use partial interval recording for more than one behavior at a time?

Yes, PIR can track more than one behavior at a time by giving each behavior its own row on the data sheet. Keep the list short, since how well observers score may depend on how many behaviors they track at once.

Can you use partial interval recording in a functional analysis?

Yes, you can use PIR in a functional analysis, but it's better to count or time the behavior when you can. Over 60% of published functional analysis studies counted or timed the behavior (LeBlanc and colleagues, 2020). Multielement designs switch between conditions from session to session. In these designs, Rapp and colleagues (2007) found that 10-second PIR tended to show differences between conditions that duration recording didn't. If you'd like more of your week free for assessment and treatment planning, book a demo.

Looking for a change?

Start an ABA practice today — with none of the admin burden.

Get Started

RELATED ARTICLES

TABLE OF CONTENTS
SHARE THIS ARTICLE